Overview
Glove box with purification systemforms a sealed environment, filled with inert gas or nitrogen to the cabinets, and circulation to remove internal active substances, allowing the system always maintain high cleanliness and high purity inert gas environment (water and oxygen contents are below 1ppm)
Model list for Glove Box with Purification system
Main Parameters of Transparent Glove Box
Model No | Box Dimension | Total Dimensions | Operating Sides | Numbers of Gloves | Options |
---|---|---|---|---|---|
KGBP800S-2 | 1200*800*930mm | 1915*830*1830mm | Single | 2 | Single or double purification columns |
KGBP1000S-4 | 1200*1000*930mm | 1915*1060*1830mm | Single | 4 | Single or double purification columns |
KGBP1000D-4 | 1200*1000*930mm | 1915*1060*1830mm | Double | 4 | Single or double purification columns |
KGBP1200S-2 | 200*1200*930mm | 1915*1260*1830mm | Single | 2 | Single or double purification columns |
KGBP1200S-4 | 200*1200*930mm | 1915*1260*1830mm | Double | 4 | Single or double purification columns |
KGBP800S-3 | 1500*800*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
KGBP1000S-3 | 1500*1000*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
KGBP1000D-6 | 1500*1000*930mm | 2215*1060*1830mm | Double | 6 | Single or double purification columns |
KGBP1200S-3 | 1500*1200*930mm | 2215*1260*1830mm | Single | 3 | Single or double purification columns |
KGBP1200D-6 | 1500*1200*930mm | 2215*1260*1830mm | Double | 6 | Single or double purification columns |
KGBP800S-4 | 1900*800*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
KGBP1000S-4 | 1900*1000*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
KGBP1000D-8 | 1900*1000*930mm | 2615*1060*1830mm | Double | 8 | Single or double purification columns |
KGBP1200S-4 | 1900*1200*930mm | 2615*1260*1830mm | Single | 4 | Single or double purification columns |
KGBP1200D-8 | 1900*1200*930mm | 2615*1260*1830mm | Double | 8 | Single or double purification columns |
Working Principle
Connected with a variety of sealed containers, equipment and production lines to form a closed circulation environment ,the internal purification materials of the purification column does purification treatment with inert gas ( mainly water, oxygen elimination) enabling the system to always keep high clean and high purity inert gas environment. The working gas of the system is inert gas or nitrogen. The control gas of the system is compressed air or inert gas or nitrogen. The restoring gas for the system is inert gas or mixture of inert gas and hydrogen.
Applications
Anhydrous, anaerobic and clean, ultra-clean work environment; R&D and production of lithium-ion battery and battery materials; Semiconductor, nano materials, film preparation, catalyst agent, super capacitor, special lamps, laser welding, TIG welding, resistance welding.
Technical Parameter
THE BASIC FUNCTIONS OF THE GAS PURIFICATION SYSTEM
NAME | INTRODUCTION |
---|---|
Automatic control | Realize the automatic controlling and monitoring of the equipment operation by program control unit |
Manual/automatic gas replacement within the box | Before first using the system, “replace” the air of the box body with inert gas or nitrogen. Gas replacement can be achieved easily by using automatic box gas replacement function system provides |
Manual/automatic gas replacement within the chamber | Gas replacement within the chamber is required when the material enter the box. Gas replacement can be achieved easily by using automatic chamber gas replacement function system provides |
Gas purification control | Set the system purification be automatic after setting the required working status and outcome, then system will automatically keep the atmosphere of the box, therefore the system can finish the work in no case of personal; also we can choose manual control. |
Gas pressure control | After setting the gas pressure range and choosing automatic pressure control, the system will maintain the desired gas pressure automatically for us, also we can choose manual control. |
Foot-pedal air pressure control | Use the foot-pedal controller--controlling the gas pressure of the system through inflation and deflation. |
Restoring the purification system | Restoring of purification materials is completed by the system automatically, and we only need to provide the system restore conditions, then the system can automatically complete the restoring work for us after opening restoring, and the whole process does not need staff to monitor. |
Online condition examination | The user can use the work state examination function of the equipment unit the control system provides to observe components working condition, and check out the fault source of various functions and components. |
System parameter setting | With a system setting function, the user can set various parameters of the system to achieve desired working conditions and function set |
Data recording function | We can trace back or monitor the production or experiment through operating parameters recording of the equipment the system provides. |
Controlling gas reserving function | The reserved control gas will guarantee the equipment to continue working in a long time when the control gas source is temporarily cut off or insufficient control air is supplied. |
Circulating gas cooling standby function | A heat exchanger for cooling the circulating gas provided within the purification system, can enter individually the coolant controlling the circulating gas temperature |
Multilevel security system | The control system sets up multi-level function of safety tips, alarm and forbidden to ensure the safety of personnel and equipment |
Protection function from blocking purification circulation | When the circulating system is blocked, the control system will indicate alarm, and actively adjust the circulation velocity to protect the motor, and can also through the function check out the system’s issues that the circulates suffocated, conduit not free, filter dust collection and other issues. |
THE BASIC ACCESSORIES OF THE GAS PURIFICATION SYSTEM
NAME | INTRODUCTION |
---|---|
Water sensor | Range 0-1000ppm,used for measuring the numerical value of water content within the box, Touch screen displaying, imported brand. |
Oxygen sensor | Range 0-1000ppm,used for measuring the numerical value of oxygen content within the box, Touch screen displaying, imported brand. |
Organic solvent absorber | Volume 21L,used for absorbing the solvent gas generated in the process of using the glove box to protect purification material within the system |
KGP25 SERIES “THE PURIFICATION VOLUME 25L”
MODEL | REMARKS | BOX SIZE(mm) | Remarks |
---|---|---|---|
KGP25S | Single purification system | 800*600* | With the function of both water and oxygen elimination or of only water elimination or only oxygen elimination. Introduction of renewable/ reducible purification system |
KG25D | Double purification column | 900*650*820 |